Giant I Series (3P/3P)

PRO63300-L SERIES 10-200KVA

Online double-conversion

DSP technology guarantees high reliability

True galvanic isolation transformer design

Control designed to withstand all kinds of loads

Intelligent battery management to prolong battery lifecycle

Redundant fan design and independent ventilation enhance durable operation under harsh environment

MODEL

PRO63310-L 10KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 10KVA
Nominal Power (W) 8KW
Dimension (mm) 656 x 405 x 817 (D x W x H)
Weight (kg) 118

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default 10A,Maximum*=Capacity/Battery
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63315-L 15KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 15KVA
Nominal Power (W) 12KW
Dimension (mm) 656 x 405 x 817 (D x W x H)
Weight (kg) 120

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default 10A,Maximum*=Capacity/Battery
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63320-L 20KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 20KVA
Nominal Power (W) 16KW
Dimension (mm) 656 x 405 x 817 (D x W x H)
Weight (kg) 145

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default 10A,Maximum*=Capacity/Battery
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63330-L 30KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 30KVA
Nominal Power (W) 24KW
Dimension (mm) 656 x 405 x 941 (D x W x H)
Weight (kg) 193

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63340-L 40KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 40KVA
Nominal Power (W) 32KW
Dimension (mm) 821 x 432 x 1159 (D x W x H)
Weight (kg) 278

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63360-L 60KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 60KVA
Nominal Power (W) 48KW
Dimension (mm) 821 x 432 x 1159 (D x W x H)
Weight (kg) 365

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO63380-L 80KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 80KVA
Nominal Power (W) 64KW
Dimension (mm) 975 x 554 x 1286 (D x W x H)
Weight (kg) 471

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO633100-L 100KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 100KVA
Nominal Power (W) 80KW
Dimension (mm) 975 x 554 x 1286 (D x W x H)
Weight (kg) 573

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO633120-L 120KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 120KVA
Nominal Power (W) 96KW
Dimension (mm) 975 x 635 x 1326 (D x W x H)
Weight (kg) 650

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO633160-L 160KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 160KVA
Nominal Power (W) 128KW
Dimension (mm) 1051x705x1646 (D x W x H)
Weight (kg) 760

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PRO633200-L 200KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 200KVA
Nominal Power (W) 160KW
Dimension (mm) 1051x705x1646 (D x W x H)
Weight (kg) 840

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph+N)
Acceptable Voltage Range 285VAC ~ 475VAC
Frequency  50/60 Hz ± 10 %

INVERTER

Connection Type Terminal
Nominal Voltage 3 x 380VAC / 400VAC / 415VAC (3Ph+N) (Selectable)
Frequency 50 Hz
Max. Synchronization Speed ±1 Hz/s
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<5% (Non-linear Load)

STATIC BYPASS

Type Solid state
Voltage  3 x 380VAC/400VAC/415VAC (3Ph+N)
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%

BATTERY

Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default: 10A. Max. 40A
Charging Voltage 432 VDC (Based on 32pcs batteries)

DOWNLOAD

Document Date Version
2017-08-07 1.00
2017-08-07 1.00