MODEL
PRO63106-S/L 6KVA
GENERAL
UPS Type | Tower |
Phase | 3-phase in / 1-phase out |
Rating (VA) | 6000VA |
Nominal Power (W) | 4800W |
Standard Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 129 |
Long-run Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 84 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 3 x 360VAC / 380VAC / 400VAC (3Ph + G or 3Ph + N + G) |
Voltage Range | 286VAC ~ 476VAC @ 16 pcs of batteries 320VAC ~ 476VAC @ 18 pcs of batteries |
Frequency Range | 40 Hz ~ 55 Hz @ 50Hz system 57 Hz ~ 63 Hz @ 60Hz system |
OUTPUT
Connection Type | Terminal |
Output Voltage | 208VAC / 220VAC / 230VAC /240VAC (Selectable) |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 50 Hz |
Frequency Synchronisation Speed | 1~2 Hz/s |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≦3% THD (Linear load) ≦5% THD (Non-linear load) |
BYPASS
Connection Type | Terminal |
Input Voltage Range | 165VAC ~ 275VAC @ 16 pcs of batteries 185VAC ~ 275VAC @ 18 pcs of batteries |
Overload Capability | 1.5 In~1.8 In 30s~ 1h |
Short-circuit Capability | 1.8 In ~ >2.0 In 200ms~30s |
EFFICIENCY
Line Mode | 87% |
Battery Mode | 92% |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 6 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Numbers | 16 / 18 |
Charging Current (max) | 2A/4A/8A (selectable) |
REAR PANEL
|

PRO63108-S/L 7.5KVA
GENERAL
UPS Type | Tower |
Phase | 3-phase in / 1-phase out |
Rating (VA) | 7500VA |
Nominal Power (W) | 6000W |
Standard Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 152 |
Long-run Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 107 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 3 x 360VAC / 380VAC / 400VAC (3Ph + G or 3Ph + N + G) |
Voltage Range | 286VAC ~ 476VAC @ 16 pcs of batteries 320VAC ~ 476VAC @ 18 pcs of batteries |
Frequency Range | 40 Hz ~ 55 Hz @ 50Hz system 57 Hz ~ 63 Hz @ 60Hz system |
OUTPUT
Connection Type | Terminal |
Output Voltage | 208VAC / 220VAC / 230VAC /240VAC (Selectable) |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 50 Hz |
Frequency Synchronisation Speed | 1~2 Hz/s |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≦3% THD (Linear load) ≦5% THD (Non-linear load) |
BYPASS
Connection Type | Terminal |
Input Voltage Range | 165VAC ~ 275VAC @ 16 pcs of batteries 185VAC ~ 275VAC @ 18 pcs of batteries |
Overload Capability | 1.5 In~1.8 In 30s~ 1h |
Short-circuit Capability | 1.8 In ~ >2.0 In 200ms~30s |
EFFICIENCY
Line Mode | 87% |
Battery Mode | 92% |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 6 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Numbers | 16 / 18 |
Charging Current (max) | 2A/4A/8A (selectable) |
REAR PANEL
|

PRO63110-S/L 10KVA
GENERAL
UPS Type | Tower |
Phase | 3-phase in / 1-phase out |
Rating (VA) | 10000VA |
Nominal Power (W) | 8000W |
Standard Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 160 |
Long-run Model Dimension (mm) | 562 x 300 x 830 (D x W x H) |
Weight (kg) | 115 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 3 x 360VAC / 380VAC / 400VAC (3Ph + G or 3Ph + N + G) |
Voltage Range | 286VAC ~ 476VAC @ 16 pcs of batteries 320VAC ~ 476VAC @ 18 pcs of batteries |
Frequency Range | 40 Hz ~ 55 Hz @ 50Hz system 57 Hz ~ 63 Hz @ 60Hz system |
OUTPUT
Connection Type | Terminal |
Output Voltage | 208VAC / 220VAC / 230VAC /240VAC (Selectable) |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 50 Hz |
Frequency Synchronisation Speed | 1~2 Hz/s |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≦3% THD (Linear load) ≦5% THD (Non-linear load) |
BYPASS
Connection Type | Terminal |
Input Voltage Range | 165VAC ~ 275VAC @ 16 pcs of batteries 185VAC ~ 275VAC @ 18 pcs of batteries |
Overload Capability | 1.5 In~1.8 In 30s~ 1h |
Short-circuit Capability | 1.8 In ~ >2.0 In 200ms~30s |
EFFICIENCY
Line Mode | 87% |
Battery Mode | 92% |
BATTERY
Standard Model Type | 12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 6 hours recover to 90% capacity |
Long-run Model Type | Depending on the capacity of external batteries |
Numbers | 16 / 18 |
Charging Current (max) | 2A/4A/8A (selectable) |
REAR PANEL
|