Hybrid Series

Hybrid Inverter

Hybrid 2K-48

GENERAL

Phase 1-phase in / 1-phase out
Dimension 107 x 438 x 480mm (D x W x H)
Net Weight (kgs) 15.5
Maximum PV Input Power 2250 W
Rated Output Power 2000 W
Maximum Charging Power 1200 W

Grid-tie operation

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 300 VDC / 350 VDC
Start-up Voltage / Initial Feeding Voltage 80 VDC / 120 VDC
MPP Voltage Range 120 VDC ~ 320 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 15 A

GRID OUTPUT (AC)

Nominal Output Power 101/110/120/127 VAC
Output Voltage Range 88 - 127 VAC*
Nominal Output Current 18 A
Power Factor > 0.99

EFFICIENCY

Maximum Conversion Efficiency (DC/AC) 95%

OFF-GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage 60 - 70 VAC / 85 VAC
Acceptable Input Voltage Range 80 - 130 VAC
Maximum AC Input Current 30 A

PV INPUT (DC)

Maximum DC Voltage 350 VDC
MPP Voltage Range 150 VDC ~ 320 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 15 A
   

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 101/110/120/127 VAC
Output Waveform Pure Sinewave
Efficiency (DC to AC) 90%

HYBRID OPERATION

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 300 VDC / 350 VDC
Start-up Voltage / Initial Feeding Voltage 80 VDC / 120 VDC
MPP Voltage Range 120 VDC ~ 320 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 15 A

GRID OUTPUT (AC)

Nominal Output Power 101/110/120/127 VAC
Output Voltage Range 88 - 127 VAC*
Nominal Output Current 18 A

AC INPUT

AC Start-up Voltage / Auto Restart Voltage 60 - 70 VAC / 85 VAC
Acceptable Input Voltage Range 80 - 130 VAC
Maximum AC Input Current 30 A

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Charging Current Default 25A, 5A - 25A (Adjustable)
Hybrid Plus 3K-48

GENERAL

Phase 1-phase in / 1-phase out
Dimension 107 x 438 x 480mm (D x W x H)
Net Weight (kgs) 15.5
Maximum PV Input Power 4500 W
Rated Output Power 3000 W
Maximum Charging Power 1200 W

Grid-tie operation

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 360 VDC / 500 VDC
Start-up Voltage / Initial Feeding Voltage 116 VDC / 150 VDC
MPP Voltage Range 250 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 18 A

GRID OUTPUT (AC)

Nominal Output Power 208/220/230/240 VAC
Output Voltage Range 184 - 265 VAC*
Nominal Output Current 13 A
Power Factor > 0.99

EFFICIENCY

Maximum Conversion Efficiency (DC/AC) 96%

OFF-GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range 170 - 280 VAC
Maximum AC Input Current 30 A

PV INPUT (DC)

Maximum DC Voltage 500 VDC
MPP Voltage Range 250 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 18 A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 202/208/220/230/240 VAC
Output Waveform Pure Sinewave
Efficiency (DC to AC) 93%

HYBRID OPERATION

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 360 VDC / 500 VDC
Start-up Voltage / Initial Feeding Voltage 116 VDC / 150 VDC
MPP Voltage Range 250 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current 1 / 1 x 18 A

GRID OUTPUT (AC)

Nominal Output Power 202/208/220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC*
Nominal Output Current 13 A

AC INPUT

AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range 170 - 280 VAC
Maximum AC Input Current 30 A

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Charging Current Default 25A, 5A - 25A (Adjustable)
Hybrid Plus 5K-48

GENERAL

Phase 1-phase in / 1-phase out
Dimension 204.2 x 460 x 600mm (D x W x H)
Net Weight (kgs) 29
Maximum PV Input Power 10000 W
Rated Output Power 5000 W
Maximum Charging Power 4800 W

Grid-tie operation

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 225 VDC / 250 VDC
MPP Voltage Range 250 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 10 A

GRID OUTPUT (AC)

Nominal Output Power 208/220/230/240 VAC
Output Voltage Range 184 - 265 VAC*
Nominal Output Current 21 A
Power Factor > 0.99

EFFICIENCY

Maximum Conversion Efficiency (DC/AC) 96%

OFF-GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range 170 - 280 VAC
Maximum AC Input Current 40 A

PV INPUT (DC)

Maximum DC Voltage 900 VDC
MPP Voltage Range 250 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 10 A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 202/208/220/230/240 VAC
Output Waveform Pure Sinewave
Efficiency (DC to AC) 93%

HYBRID OPERATION

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 225 VDC / 250 VDC
MPP Voltage Range 250 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 10A

GRID OUTPUT (AC)

Nominal Output Power 202/208/220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC*
Nominal Output Current 21 A

AC INPUT

AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range 170 - 280 VAC
Maximum AC Input Current 40 A

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 5A - 100A (Adjustable)
Hybrid 10K-48

GENERAL

Phase 3-phase in / 3-phase out
Dimension 167.5 x 500 x 622mm (D x W x H)
Net Weight (kgs) 45
Maximum PV Input Power 14850 W
Rated Output Power 10000 W
Maximum Charging Power 9600 W

Grid-tie operation

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 400 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6 A

GRID OUTPUT (AC)

Nominal Output Power 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 265 VAC* per phase
Nominal Output Current 14.5A per phase
Power Factor > 0.99

EFFICIENCY

Maximum Conversion Efficiency (DC/AC) 96%

OFF-GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC per phase /
180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 40 A

PV INPUT (DC)

Maximum DC Voltage 900 VDC
MPP Voltage Range 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6 A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure Sinewave
Efficiency (DC to AC) 91%

HYBRID OPERATION

PV INPUT (DC)

Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6 A

GRID OUTPUT (AC)

Nominal Output Power 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 264.5 VAC* per phase
Nominal Output Current 14.5 A per phase

AC INPUT

AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC per phase /
180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 40 A

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 10A - 200A (Adjustable)