Hybrid 2K-48
GENERAL
Phase | 1-phase in / 1-phase out |
Dimension | 107 x 438 x 480mm (D x W x H) |
Net Weight (kgs) | 15.5 |
Maximum PV Input Power | 2250 W |
Rated Output Power | 2000 W |
Maximum Charging Power | 1200 W |
Grid-tie operation
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 300 VDC / 350 VDC |
Start-up Voltage / Initial Feeding Voltage | 80 VDC / 120 VDC |
MPP Voltage Range | 120 VDC ~ 320 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 15 A |
GRID OUTPUT (AC)
Nominal Output Power | 101/110/120/127 VAC |
Output Voltage Range | 88 - 127 VAC* |
Nominal Output Current | 18 A |
Power Factor | > 0.99 |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) | 95% |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage | 60 - 70 VAC / 85 VAC |
Acceptable Input Voltage Range | 80 - 130 VAC |
Maximum AC Input Current | 30 A |
PV INPUT (DC)
Maximum DC Voltage | 350 VDC |
MPP Voltage Range | 150 VDC ~ 320 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 15 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 101/110/120/127 VAC |
Output Waveform | Pure Sinewave |
Efficiency (DC to AC) | 90% |
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 300 VDC / 350 VDC |
Start-up Voltage / Initial Feeding Voltage | 80 VDC / 120 VDC |
MPP Voltage Range | 120 VDC ~ 320 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 15 A |
GRID OUTPUT (AC)
Nominal Output Power | 101/110/120/127 VAC |
Output Voltage Range | 88 - 127 VAC* |
Nominal Output Current | 18 A |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage | 60 - 70 VAC / 85 VAC |
Acceptable Input Voltage Range | 80 - 130 VAC |
Maximum AC Input Current | 30 A |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | Default 25A, 5A - 25A (Adjustable) |
Hybrid Plus 3K-48
GENERAL
Phase | 1-phase in / 1-phase out |
Dimension | 107 x 438 x 480mm (D x W x H) |
Net Weight (kgs) | 15.5 |
Maximum PV Input Power | 4500 W |
Rated Output Power | 3000 W |
Maximum Charging Power | 1200 W |
Grid-tie operation
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A |
GRID OUTPUT (AC)
Nominal Output Power | 208/220/230/240 VAC |
Output Voltage Range | 184 - 265 VAC* |
Nominal Output Current | 13 A |
Power Factor | > 0.99 |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) | 96% |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 30 A |
PV INPUT (DC)
Maximum DC Voltage | 500 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 202/208/220/230/240 VAC |
Output Waveform | Pure Sinewave |
Efficiency (DC to AC) | 93% |
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A |
GRID OUTPUT (AC)
Nominal Output Power | 202/208/220/230/240 VAC |
Output Voltage Range | 184 - 264.5 VAC* |
Nominal Output Current | 13 A |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 30 A |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | Default 25A, 5A - 25A (Adjustable) |
Hybrid Plus 5K-48
GENERAL
Phase | 1-phase in / 1-phase out |
Dimension | 204.2 x 460 x 600mm (D x W x H) |
Net Weight (kgs) | 29 |
Maximum PV Input Power | 10000 W |
Rated Output Power | 5000 W |
Maximum Charging Power | 4800 W |
Grid-tie operation
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 225 VDC / 250 VDC |
MPP Voltage Range | 250 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 10 A |
GRID OUTPUT (AC)
Nominal Output Power | 208/220/230/240 VAC |
Output Voltage Range | 184 - 265 VAC* |
Nominal Output Current | 21 A |
Power Factor | > 0.99 |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) | 96% |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 40 A |
PV INPUT (DC)
Maximum DC Voltage | 900 VDC |
MPP Voltage Range | 250 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 10 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 202/208/220/230/240 VAC |
Output Waveform | Pure Sinewave |
Efficiency (DC to AC) | 93% |
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 225 VDC / 250 VDC |
MPP Voltage Range | 250 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 10A |
GRID OUTPUT (AC)
Nominal Output Power | 202/208/220/230/240 VAC |
Output Voltage Range | 184 - 264.5 VAC* |
Nominal Output Current | 21 A |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 40 A |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | Default 60A, 5A - 100A (Adjustable) |
Hybrid 10K-48
GENERAL
Phase | 3-phase in / 3-phase out |
Dimension | 167.5 x 500 x 622mm (D x W x H) |
Net Weight (kgs) | 45 |
Maximum PV Input Power | 14850 W |
Rated Output Power | 10000 W |
Maximum Charging Power | 9600 W |
Grid-tie operation
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
MPP Voltage Range | 400 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 18.6 A |
GRID OUTPUT (AC)
Nominal Output Power | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 - 265 VAC* per phase |
Nominal Output Current | 14.5A per phase |
Power Factor | > 0.99 |
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) | 96% |
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage | 120 - 140 VAC per phase / 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 40 A |
PV INPUT (DC)
Maximum DC Voltage | 900 VDC |
MPP Voltage Range | 400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 18.6 A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform | Pure Sinewave |
Efficiency (DC to AC) | 91% |
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
MPP Voltage Range | 400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 18.6 A |
GRID OUTPUT (AC)
Nominal Output Power | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 - 264.5 VAC* per phase |
Nominal Output Current | 14.5 A per phase |
AC INPUT
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC per phase / 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 40 A |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | Default 60A, 10A - 200A (Adjustable) |