Hybrid V II 1.5K-12
GENERAL
Dimension | 100 x 300 x 440mm (D x W x H) |
Net Weight (kgs) | 8 |
INPUT
Max. PV Array Power | 2000W |
Rated Output Power | 1500W |
Maximum PV Array Open Circuit Voltage | 400 VDC |
MPPT Range @ Operating Voltage | 120 VDC ~ 380 VDC |
MPP Tracker Number | 1 |
GRID OUTPUT (AC)
Nominal Output Power | 220/230/240 VAC |
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable) |
Nominal Output Current | 6.5 A |
Power Factor | > 0.99 |
GRID INPUT
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
Maximum AC Input Current | 30A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 220/230/240 VAC |
Output Waveform | Pure sine wave |
Efficiency (DC/AC) | 93% |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Solar Charge Current | 30 A |
Maximum AC Charge Current | 40 A |
Maximum Charge Current | 40 A |
INTERFACE
Parallel Function | N/A |
Communication Ports | USB or RS232/Dry-Contact |
Hybrid V II 3K-48
GENERAL
Dimension | 120 x 295 x 468mm (D x W x H) |
Net Weight (kgs) | 11 |
INPUT
Max. PV Array Power | 4000W |
Rated Output Power | 3000W |
Maximum PV Array Open Circuit Voltage | 450 VDC |
MPPT Range @ Operating Voltage | 120 VDC ~ 430 VDC |
MPP Tracker Number | 1 |
GRID OUTPUT (AC)
Nominal Output Power | 220/230/240 VAC |
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable) |
Nominal Output Current | 13 A |
Power Factor | > 0.99 |
GRID INPUT
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
Maximum AC Input Current | 40A |
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage | 220/230/240 VAC |
Output Waveform | Pure sine wave |
Efficiency (DC/AC) | 93% |
BATTERY & CHARGER
Nominal DC Voltage | 48 VDC |
Maximum Solar Charge Current | 60 A |
Maximum AC Charge Current | 60 A |
Maximum Charge Current | 60 A |
INTERFACE
Parallel Function | Yes, 9 units |
Communication Ports | USB or RS232/Dry-Contact |