Hybrid V Series

Hybrid Inverter

Hybrid V 1K-12

GENERAL

Dimension 100 x 300 x 440mm (D x W x H)
Net Weight (kgs) 8

INPUT

Max. PV Array Power 1000W
Rated Output Power 1000W
Maximum PV Array Open Circuit Voltage 145 VDC
MPPT Range @ Operating Voltage 15 VDC ~ 115 VDC
MPP Tracker Number 1

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current 4.3 A
Power Factor > 0.99

GRID INPUT

Acceptable Input Voltage Range 90 - 280 VAC or 170 - 280 VAC
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 30A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC/AC) 93%

BATTERY & CHARGER

Nominal DC Voltage 12 VDC
Maximum Solar Charge Current 80 A
Maximum AC Charge Current 60 A
Maximum Charge Current 140 A

INTERFACE

Parallel Function N/A
External Safety Box (Optional) Yes
Communication Ports USB or RS232/Dry-Contact
Hybrid V 2K-24

GENERAL

Dimension 100 x 300 x 440mm (D x W x H)
Net Weight (kgs) 8

INPUT

Max. PV Array Power 2000W
Rated Output Power 2000W
Maximum PV Array Open Circuit Voltage 145 VDC
MPPT Range @ Operating Voltage 30 VDC ~ 115 VDC
MPP Tracker Number 1

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current 8.7 A
Power Factor > 0.99

GRID INPUT

Acceptable Input Voltage Range 90 - 280 VAC or 170 - 280 VAC
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 30A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC/AC) 93%

BATTERY & CHARGER

Nominal DC Voltage 24 VDC
Maximum Solar Charge Current 80 A
Maximum AC Charge Current 60 A
Maximum Charge Current 140 A

INTERFACE

Parallel Function N/A
External Safety Box (Optional) Yes
Communication Ports USB or RS232/Dry-Contact
Hybrid V 3K-48

GENERAL

Dimension 120 x 295 x 468mm (D x W x H)
Net Weight (kgs) 11

INPUT

Max. PV Array Power 4000W
Rated Output Power 3000W
Maximum PV Array Open Circuit Voltage 145 VDC
MPPT Range @ Operating Voltage 60 VDC ~ 115 VDC
MPP Tracker Number 1

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current 13 A
Power Factor > 0.99

GRID INPUT

Acceptable Input Voltage Range 90 - 280 VAC or 170 - 280 VAC
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 40A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC/AC) 93%

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Solar Charge Current 80 A
Maximum AC Charge Current 60 A
Maximum Charge Current 140 A

INTERFACE

Parallel Function Yes
External Safety Box (Optional) Yes
Communication Ports USB or RS232/Dry-Contact
Hybrid V 4K-48

GENERAL

Dimension 120 x 295 x 468mm (D x W x H)
Net Weight (kgs) 11

INPUT

Max. PV Array Power 4000W
Rated Output Power 4000W
Maximum PV Array Open Circuit Voltage 145 VDC
MPPT Range @ Operating Voltage 60 VDC ~ 115 VDC
MPP Tracker Number 1

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current 17.4 A
Power Factor > 0.99

GRID INPUT

Acceptable Input Voltage Range 90 - 280 VAC or 170 - 280 VAC
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 40A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC/AC) 93%

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Solar Charge Current 80 A
Maximum AC Charge Current 60 A
Maximum Charge Current 140 A

INTERFACE

Parallel Function Yes
External Safety Box (Optional) Yes
Communication Ports USB or RS232/Dry-Contact
Hybrid V 5K-48

GENERAL

Dimension 190 x 295 x 483mm (D x W x H)
Net Weight (kgs) 16

INPUT

Max. PV Array Power 6000W
Rated Output Power 5000W
Maximum PV Array Open Circuit Voltage 145 VDC
MPPT Range @ Operating Voltage 60 VDC ~ 115 VDC
MPP Tracker Number 2

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current 21.7 A
Power Factor > 0.99

GRID INPUT

Acceptable Input Voltage Range 90 - 280 VAC or 170 - 280 VAC
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 40A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC/AC) 93%

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Solar Charge Current 120 A
Maximum AC Charge Current 60 A
Maximum Charge Current 180 A

INTERFACE

Parallel Function Yes
External Safety Box (Optional) Yes
Communication Ports USB or RS232/Dry-Contact