Hybrid VT II

Hybrid Inverter

Pure sine wave output

Self-consumption and Feed-in to the grid

Programmable supply priority for PV, Battery or Grid

User-adjustable charging current and voltage

Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup

Monitoring software for real-time statu s display and control

Hybrid VT II 6KM-48

GENERAL

Phase 3-phase in / 3-phase out
Dimension D x W x H (mm) 588 x 260 x 655
Net Weight (kgs) 36

INPUT

Max. PV Array Power 9000 W
Rated Output Power 6000 W
Maximum PV Array Open Circuit Voltage 450 VDC
MPPT Range @ Operating Voltage 120 VDC ~ 430 VDC
MPP Tracker Number 3

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC (P-N) 380/400/415 VAC (P-P)
Output Voltage Range 195 - 253 VAC per phase
Nominal Output Current 8.7 A per phase
Power Factor > 0.99

GRID INPUT

AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 20 A per phase

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC (P-N) 380/400/415 VAC (P-P)
Output Waveform Pure sine wave
Efficiency (DC to AC) 90%

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Solar Charge Current 180 A
Maximum AC Charge Current 180 A
Maximum Charge Current 180 A

INTERFACE

Communication Ports USB, RS-232 and dry contact
Hybrid VT II 9KM-48

GENERAL

Phase 3-phase in / 3-phase out
Dimension D x W x H (mm) 588 x 260 x 655
Net Weight (kgs) 37.5

INPUT

Max. PV Array Power 12000W
Rated Output Power 9000W
Maximum PV Array Open Circuit Voltage 450 VDC
MPPT Range @ Operating Voltage 120 VDC ~ 430 VDC
MPP Tracker Number 3

GRID OUTPUT (AC)

Nominal Output Power 220/230/240 VAC (P-N) 380/400/415 VAC (P-P)
Output Voltage Range 195 - 253 VAC per phase
Nominal Output Current 13 A per phase
Power Factor > 0.99

GRID INPUT

AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Frequency Range 50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current 30 A per phase

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage 220/230/240 VAC (P-N) 380/400/415 VAC (P-P)
Output Waveform Pure sine wave
Efficiency (DC to AC) 90%

BATTERY & CHARGER

Nominal DC Voltage 48 VDC
Maximum Solar Charge Current 180 A
Maximum AC Charge Current 180 A
Maximum Charge Current 180 A

INTERFACE

Communication Ports USB, RS-232 and dry contact

DOWNLOAD

Document Date Version
2017-08-07 1.00
2017-08-07 1.00

You may also like…

Hybrid Inverter

Hybrid Inverter

Hybrid Inverter

Hybrid  Inverter