Master II Series (1P/1P)

PRO800-ES/EL SERIES 1-3KVA

True double-conversion online UPS

Wide input voltage range
(110-300 VAC, 55-150 VAC)

Input power factor correction 0.99

Programmable power management outlets

Emergency power off function (EPO)

Very high surge immunity up to 7KV, 13KA, 1300J

MODEL

PRO801-ES/EL 1KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 1000
Nominal Power (W) 900
Standard Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 12.5
Long-run Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 5.8

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Based on load at 50%)

160-300 VAC (Based on load at 100%)

Frequency Range 40 Hz ~ 70 Hz
Power Factor ≧0.99
THDi ≦ 5% @100~130VAC or 205-245VAC

THDU < 1.6% @ input and full linear load condition with battery fully charged

OUTPUT

Connection Type 4 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦2% THD (Linear load)

≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 second
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys,LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 7Ah
Numbers 3
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers 3
Charging Current (max) 1A/2A/4A/6A/8A (Selectable via LCD setting)

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection (Only available for L model)
  11. Output terminal
  12. Output circuit breaker
  13. Cooling fan
PRO8015-ES/EL 1.5KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 1500
Nominal Power (W) 1350
Standard Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 13.8
Long-run Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 5.8

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Based on load at 50%)

160-300 VAC (Based on load at 100%)

Frequency Range 40 Hz ~ 70 Hz
Power Factor ≧0.99
THDi ≦ 5% @100~130VAC or 205-245VAC

THDU < 1.6% @ input and full linear load condition with battery fully charged

OUTPUT

Connection Type 4 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦2% THD (Linear load)

≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 second
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD  Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 3
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers 3
Charging Current (max) 1A/2A/4A/6A/8A (Selectable via LCD setting)

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection (Only available for L model)
  11. Output terminal
  12. Output circuit breaker
  13. Cooling fan
PRO802-ES/EL 2KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 2000
Nominal Power (W) 1800
Standard Model

Dimension (mm)

421 x 190 x 318 (D x W x H)
Weight (kg) 25.8
Long-run Model

Dimension (mm)

421 x 190 x 318 (D x W x H)
Weight (kg) 12

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Based on load at 50%)

160-300 VAC (Based on load at 100%)

Frequency Range 40 Hz ~ 70 Hz
Power Factor ≧0.99
THDi ≦ 5% @100~130VAC or 205-245VAC

THDU < 1.6% @ input and full linear load condition with battery fully charged

OUTPUT

Connection Type 8 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦2% THD (Linear load)

≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 second
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 7Ah
Numbers 6
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 6
Charging Current (max) 1A/2A/4A/6A/8A (Selectable via LCD setting)

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection (Only available for L model)
  11. Output terminal
  12. Output circuit breaker
  13. Cooling fan
PRO803-ES/EL 3KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 3000
Nominal Power (W) 2700
Standard Model

Dimension (mm)

421 x 190 x 318 (D x W x H)
Weight (kg) 27
Long-run Model

Dimension (mm)

421 x 190 x 318 (D x W x H)
Weight (kg) 13.8

INPUT

Connection Type IEC 320-C20
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Based on load at 50%)

160-300 VAC (Based on load at 100%)

Frequency Range 40 Hz ~ 70 Hz
Power Factor ≧0.99
THDi ≦ 5% @100~130VAC or 205-245VAC

THDU < 1.6% @ input and full linear load condition with battery fully charged

OUTPUT

Connection Type 6 x IEC 320-C13

Terminal

Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦2% THD (Linear load)

≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 second
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 6
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 6
Charging Current (max) 1A/2A/4A/6A/8A (Selectable via LCD setting)

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection (Only available for L model)
  11. Output terminal
  12. Output circuit breaker
  13. Cooling fan

DOWNLOAD

Document Date Version
2017-08-07 1.00
2017-08-07 1.00

You may also like…

PRO800-QRS/QRL SERIES 1-10KVA

PRO800-QS/QL SERIES 1-10KVA

PRO83300-ES/EL SERIES 10-30KVA

PRO83100-ERS/ERL SERIES 10-20KVA