Master II+ Series (3P/1P)

PRO83100-ES/EL SERIES 10-30KVA

True double-conversion

DSP technology guarantees high performance

Output power factor 0.9

Wide input voltage range (110-300 VAC)

Active power factor correction in all phases

Built-in phase auto adapt function simplifies
wire installation

MODEL

PRO83110-ES/EL 10KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 1 phase out
Rating (VA) 10000VA
Nominal Power (W) 9000W
Standard Model

Dimension (mm)

592 x 250 x 576 (D x W x H)
Weight (kg) 83
Long-run Model

Dimension (mm)

592 x 250 x 576 (D x W x H)
Weight (kg) 28

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load
THDi < 6% @ 100% load

OUTPUT

Connection Type Terminal

2 x IEC 320-C13

Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)*
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 4A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4.  Share current port
    (only available for parallel configuration)
  5.  Parallel port (only available for parallel configuration)
  6.  Intelligent slot
  7.  Maintenance bypass switch
  8.  Line input circuit breaker
  9. Output circuit breaker for receptacles
  10. Output receptacles: connect to mission-critical loads
  11. Input/Output terminal
  12.  External battery connector/terminal
    (only available for Long-run model)
  13. Input/Output/Battery terminal
  14. Cooling Fan
PRO83115-ES/EL 15KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 1 phase out
Rating (VA) 15000VA
Nominal Power (W) 13500W
Standard Model

Dimension (mm)

815 x 250 x 826 (D x W x H)
Weight (kg) 164
Long-run Model

Dimension (mm)

592 x 250 x 576 (D x W x H)
Weight (kg) 40

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load
THDi < 6% @ 100% load

OUTPUT

Connection Type Terminal
Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)* x 2 strings
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 8A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4.  Share current port
    (only available for parallel configuration)
  5.  Parallel port (only available for parallel configuration)
  6.  Intelligent slot
  7.  Maintenance bypass switch
  8.  Line input circuit breaker
  9. Output circuit breaker for receptacles
  10. Output receptacles: connect to mission-critical loads
  11. Input/Output terminal
  12.  External battery connector/terminal
    (only available for Long-run model)
  13. Input/Output/Battery terminal
  14. Cooling Fan
PRO83120-ES/EL 20KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 1 phase out
Rating (VA) 20000VA
Nominal Power (W) 18000W
Standard Model

Dimension (mm)

815 x 250 x 826 (D x W x H)
Weight (kg) 164
Long-run Model

Dimension (mm)

592 x 250 x 576 (D x W x H)
Weight (kg) 40

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load
THDi < 6% @ 100% load

OUTPUT

Connection Type Terminal
Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)* x 2 strings
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 8A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4.  Share current port
    (only available for parallel configuration)
  5.  Parallel port (only available for parallel configuration)
  6.  Intelligent slot
  7.  Maintenance bypass switch
  8.  Line input circuit breaker
  9. Output circuit breaker for receptacles
  10. Output receptacles: connect to mission-critical loads
  11. Input/Output terminal
  12.  External battery connector/terminal
    (only available for Long-run model)
  13. Input/Output/Battery terminal
  14. Cooling Fan
PRO83130-ES/EL 30KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 1 phase out
Rating (VA) 30000VA
Nominal Power (W) 27000W
Standard Model

Dimension (mm)

815 x 300 x 1000 (D x W x H)
Weight (kg) 234
Long-run Model

Dimension (mm)

815 x 250 x 826 (D x W x H)
Weight (kg) 64

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load

305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load
THDi < 6% @ 100% load

OUTPUT

Connection Type Terminal
Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)* x 3 strings
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 12A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4.  Share current port
    (only available for parallel configuration)
  5.  Parallel port (only available for parallel configuration)
  6.  Intelligent slot
  7.  Maintenance bypass switch
  8.  Line input circuit breaker
  9. Output circuit breaker for receptacles
  10. Output receptacles: connect to mission-critical loads
  11. Input/Output terminal
  12.  External battery connector/terminal
    (only available for Long-run model)
  13. Input/Output/Battery terminal
  14. Cooling Fan

DOWNLOAD

Document Date Version
2017-08-07 1.00
2017-08-07 1.00

You may also like…

PRO800-ERS/ERL SERIES 1-3KVA

PRO83100-ERS/ERL SERIES 10-20KVA

PRO800-QS/QL SERIES 1-10KVA

PRO800-ES/EL SERIES 1-3KVA

PRO800-QRS/QRL SERIES 1-10KVA