Master II+ Series (3P/3P) – Rack

PRO83300-ERS/ERL SERIES 10-20KVA

True double-conversion

DSP technology guarantees high performance

Output power factor 0.9

50/60Hz Frequency Converter Mode

Active power factor correction in all phases

ECO mode operation for energy saving

MODEL

PRO83310-ERS/ERL 10KVA

GENERAL

UPS Type Rack
Phase 3 phase in / 3 phase out
Rating (VA) 10000VA
Nominal Power (W) 9000W
Standard Model

Dimension (mm)

UPS: 668 x 438 x 266 [6U] (D x W x H)

Battery pack: 580 x 438 x 133 [3U] (D x W x H)

Weight (kg) UPS unit: 42

Battery pack: 63

Long-run Model

Dimension (mm)

668 x 438 x 266 [6U] (D x W x H)
Weight (kg) 42

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) at 50% load

305-478 VAC (3-phase) at 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)**
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 4A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4. Share current port (only available for parallel configuration)
  5. Parallel port (only available for parallel configuration)
  6. Intelligent slot
  7. External battery connector (only available for Long-run model)
  8. Line input circuit breaker
  9. Output Grounding terminal
  10. Output terminal: connect to mission-critical loads
  11. Utility input terminal
  12. External maintenance bypass switch port
  13. Cooling fan
PRO83315-ERS/ERL 15KVA

GENERAL

UPS Type Rack
Phase 3 phase in / 3 phase out
Rating (VA) 15000VA
Nominal Power (W) 13500W
Standard Model

Dimension (mm)

UPS: 668 x 438 x 266 [6U] (D x W x H)

Battery pack: 580 x 438 x 133 [3U] x 2 pcs (D x W x H)

Weight (kg) UPS unit: 42

Battery pack: 63 x 2 pcs

Long-run Model

Dimension (mm)

668 x 438 x 266 [6U] (D x W x H)
Weight (kg) 45

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) at 50% load

305-478 VAC (3-phase) at 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)**x 2 strings
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 4A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4. Share current port (only available for parallel configuration)
  5. Parallel port (only available for parallel configuration)
  6. Intelligent slot
  7. External battery connector (only available for Long-run model)
  8. Line input circuit breaker
  9. Output Grounding terminal
  10. Output terminal: connect to mission-critical loads
  11. Utility input terminal
  12. External maintenance bypass switch port
  13. Cooling fan
PRO83320-ERS/ERL 20KVA

GENERAL

UPS Type Rack
Phase 3 phase in / 3 phase out
Rating (VA) 20000VA
Nominal Power (W) 18000W
Standard Model

Dimension (mm)

UPS: 668 x 438 x 266 [6U] (D x W x H)

Battery pack: 580 x 438 x 133 [3U] x 2 pcs (D x W x H)

Weight (kg) UPS unit: 42

Battery pack: 63 x 2 pcs

Long-run Model

Dimension (mm)

668 x 438 x 266 [6U] (D x W x H)
Weight (kg) 45

INPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Range 190-520 VAC (3-phase) at 50% load

305-478 VAC (3-phase) at 100% load

Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧0.99 @ 100% Load

OUTPUT

Connection Type Terminal
Nominal Voltage 3x 380/400/415 (3Ph+N)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)

≦5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 20 (18 - 20 adjustable)**x 2 strings
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers Depending on the capacity of external batteries
Charging Current (max) 4A

REAR PANEL

  1. RS-232 communication port
  2. USB communication port
  3. Emergency power off function connector (EPO connector)
  4. Share current port (only available for parallel configuration)
  5. Parallel port (only available for parallel configuration)
  6. Intelligent slot
  7. External battery connector (only available for Long-run model)
  8. Line input circuit breaker
  9. Output Grounding terminal
  10. Output terminal: connect to mission-critical loads
  11. Utility input terminal
  12. External maintenance bypass switch port
  13. Cooling fan

DOWNLOAD

Document Date Version
2017-08-07 1.00
2017-08-07 1.00

You may also like…

PRO83100-ERS/ERL SERIES 10-20KVA

PRO800-QS/QL SERIES 1-10KVA

PRO800-ES/EL SERIES 1-3KVA

PRO83300-FS/FL SERIES 30-200KVA

PRO800-ERS/ERL SERIES 1-3KVA