Accessories

MODEL

MBS16-R (I/U/S/N) (*)

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 1000
Nominal Power (W) 800
Standard Model

Dimestions WxDxH (mm)

282 x 145 x 220
Weight (kg) 9.8
Long-run Model

Dimestions WxDxH (mm)

282 x 145 x220
Weight (kg) 4.1

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Load at 50%)

160-280 VAC (Load at 100%)

Frequency Range 45 ~ 70 Hz
Power Factor >= 0.99

OUTPUT

Connection Type 3 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz
Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every seconds
Fault Continuously sounding
LED Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys
Communication Smart RS232*

Emergency Power Off (EPO) (Optional)

*Support Windows, Linux, Mac

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 2
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Dependent
Number 2/3
Charging Current (max) 1A / 2A / 4A / 6A Adjustable
MBS16-T (I/U/S/N) (*)

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 1000
Nominal Power (W) 800
Standard Model

Dimestions WxDxH (mm)

282 x 145 x 220
Weight (kg) 9.8
Long-run Model

Dimestions WxDxH (mm)

282 x 145 x220
Weight (kg) 4.1

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Load at 50%)

160-280 VAC (Load at 100%)

Frequency Range 45 ~ 70 Hz
Power Factor >= 0.99

OUTPUT

Connection Type 3 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz
Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every seconds
Fault Continuously sounding
LED Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys
Communication Smart RS232*

Emergency Power Off (EPO) (Optional)

*Support Windows, Linux, Mac

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 2
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Dependent
Number 2/3
Charging Current (max) 1A / 2A / 4A / 6A Adjustable

DOWNLOAD