MODEL

PRO73310-ES/EL 10KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 10KVA
Nominal Power (W) 9KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 83 (without batteries) 210 (w/built-in batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.4 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type 12V 4.5Ah
Back-up Time (minutes) 5
Max. Charging Current 23.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73315-ES/EL 15KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 15KVA
Nominal Power (W) 13.5KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 88 (without batteries) 212 (w/built-in batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.4 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type 12V 4.5Ah
Back-up Time (minutes) 3
Max. Charging Current 23.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73320-ES/EL 20KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 20KVA
Nominal Power (W) 18KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 95 (without batteries) 215 (w/built-in batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.4 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type 12V 7Ah
Back-up Time (minutes) 5
Max. Charging Current 23.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73330-ES/EL 30KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 30KVA
Nominal Power (W) 27KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 113 (without batteries) 310 (w/built-in batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.2 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type 12V 9Ah
Back-up Time (minutes) 3
Max. Charging Current 23.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73340-ES/EL 40KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 40KVA
Nominal Power (W) 36KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 120 (without batteries) 400 (w/built-in batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.2 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type 12V 12Ah
Back-up Time (minutes) 3
Max. Charging Current 47 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73360-EL 60KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 60KVA
Nominal Power (W) 54KW
Dimension (mm) 770 x 450 x 1100 (D x W x H)
Weight (kg) 185 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.2 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 47 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO73380-EL 80KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 80KVA
Nominal Power (W) 72KW
Dimension (mm) 805 x 590 x 1320 (D x W x H)
Weight (kg) 265 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 2.8 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 70.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO733100-EL 100KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 100KVA
Nominal Power (W) 90KW
Dimension (mm) 805 x 590 x 1320 (D x W x H)
Weight (kg) 290 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.2 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 70.5 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO733120-EL 120KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 120KVA
Nominal Power (W) 108KW
Dimension (mm) 805 x 590 x 1320 (D x W x H)
Weight (kg) 290 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.2 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 188 A

REAR PANEL

  1. Relay interface
  2. Emergency Power Off (EPO)
  3. RS-232 COM ports
  4. Intelligent Slot
  5. Input circuit breaker
  6. Maintenance bypass switch
  7. Output switch
  8. Battery switch
  9. Input/Output/Battery Terminal
  10. Parallel port (only available for parallel configuration)
PRO733160-EL 160KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 160KVA
Nominal Power (W) 144KW
Dimension (mm) 850 x 900 x 1900 (D x W x H)
Weight (kg) 540 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.0 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 188 A

REAR PANEL

1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slot 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 10. Parallel port (only available for parallel configuration)
PRO733200-EL 200KVA

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 200KVA
Nominal Power (W) 180KW
Dimension (mm) 850 x 900 x 1900 (D x W x H)
Weight (kg) 550 (without batteries)

INPUT

Connection Type Terminal
Nominal Voltage 3 x 400 V (3Ph+N)
Voltage Range +15% or –20%
Frequency Range 50 / 60 Hz ±5 %
Power Factor 1.0
THDi < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load

INVERTER

Connection Type Terminal
NominalVoltage 3 x 400 V (3Ph+N)
Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%
Max. Synchronisation Speed 10 Hz/s
Admissible Crest Factor 3.0 : 1
Harmonic Distortion < 0.5% (Linear Load) < 1.5% (Non-linear Load)

MAINTENANCE BYPASS

Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz

BATTERY

Type -
Back-up Time (minutes) -
Max. Charging Current 188 A

REAR PANEL

1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slot 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 10. Parallel port (only available for parallel configuration)

DOWNLOAD

Document Date Version
2017-08-07 1.00

You may also like…

PRO800-QS/QL SERIES 1-10KVA

PRO SFT SERIES 650VA -2000VA

PRO600-S/L SERIES 6-10KVA

PRO63100-GL SERIES 10-40KVA