MODEL
GENERAL
UPS Type | Rack |
Phase | Single phase with ground |
Capacity | 1000VA / 800W |
Dimension (mm) | 477 x 438 x 44 (D x W x H) |
Weight (kg) | 12.6 |
INPUT
Connection Type | Terminal |
Low Line Transfer | 80VAC/70VAC/60VAC/55VAC ± 5 %
160VAC/140VAC/120VAC/110VAC ± 5 % |
Low Line Comeback | 85VAC/75VAC/65VAC/60VAC ± 5 %
170VAC/150VAC/130VAC/120VAC ± 5 % |
Frequency Range | 40Hz ~70Hz |
Power Factor | ≧ 0.99 @ Nominal voltage (full load) |
OUTPUT
Connection Type | Terminal |
Nominal Voltage | 110/120 VAC or 220/230/240 VAC |
AC Voltage Regulation | ± 1% |
Frequency Range (Synchronized) | 57 ~ 63 Hz or 47 ~ 53 Hz |
Overload | 100%~105%: audible warning
105%-130%: UPS shuts down in 10 seconds at battery mode or transfers to bypass mode after 2min when the utility is normal. >130%: UPS shuts down immediately at battery mode or transfer to bypass mode after 10s when the utility is normal |
Current Crest Ratio | 5:1 for 110/120 VAC system
3:1 for 220/230/240 VAC systems |
Harmonic Distortion | ≦3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load) |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
TYPE | 6 V / 9 AH |
Numbers | 4 |
Recharge Time | 9 hours recover to 90% capacity |
Real Panel
1. AC input
2. Output receptacle: connect to mission-critical loads 3. Programmable outlets: connect to non-critical loads 4. USB/RS-232 serial communication port 5. ROO/RPO function connector 6. SNMP intelligent slot 9. Cooling fan |

GENERAL
UPS Type | Rack |
Phase | Single phase with ground |
Capacity | 1000VA / 800W |
Dimension (mm) | 300 x 438 x 44 (D x W x H) |
Weight (kg) | 6 |
INPUT
Connection Type | Terminal |
Low Line Transfer | 80VAC / 70VAC / 60VAC / 55VAC ± 5 %
160VAC/140VAC/120VAC/110VAC ± 5 % |
Low Line Comeback | 85VAC/75VAC/65VAC/60VAC ± 5 %
170VAC/150VAC/130VAC/120VAC ± 5 % |
Frequency Range | 40Hz ~70Hz |
Power Factor | ≧ 0.99 @ Nominal voltage (full load) |
OUTPUT
Connection Type | Terminal |
Nominal Voltage | 110/120 VAC or 220/230/240 VAC |
AC Voltage Regulation | ± 1% |
Frequency Range (Synchronized) | 57 ~ 63 Hz or 47 ~ 53 Hz |
Overload | 100%~105%: audible warning
105%-130%: UPS shuts down in 10 seconds at battery mode or transfers to bypass mode after 2min when the utility is normal. >130%: UPS shuts down immediately at battery mode or transfer to bypass mode after 10s when the utility is normal |
Current Crest Ratio | 5:1 for 110/120 VAC system
3:1 for 220/230/240 VAC systems |
Harmonic Distortion | ≦3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load) |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
Type
Numbers Recharge Time |
Lithium-iron battery or Sealed Lead-acid battery (Battery voltage: 48VDC) |
Real Panel
1. AC input
2. Output receptacle: connect to mission-critical loads 4. USB/RS-232 serial communication port 6. SNMP intelligent slot 7. Dry contact 8. External battery connector 9. Cooling fan |