MODEL
GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 1000 |
Nominal Power (W) | 900 |
Standard Model
Dimension (mm) |
310 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 12 |
Long-run Model
Dimension (mm) |
310 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 9 |
INPUT
Connection Type | IEC 320-C14 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%)
160-280 VAC (Load at 100%) |
Frequency Range | 40 ~ 70 Hz |
Power Factor | ≥ 0.99 |
OUTPUT
Connection Type |
Standard Model
Long-Run Model
|
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load)
≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port |
BATTERY
Standard Model
Type |
12V / 9Ah |
Numbers | 2 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model
Type |
Depending on the capacity of external batteries |
Number | 3 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input
2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles (IEC C13) 8. Output receptacles (Universal outlet) |


GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 2000 |
Nominal Power (W) | 1800 |
Standard Model
Dimension (mm) |
410 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 19 |
Long-run Model
Dimension (mm) |
410 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 12 |
INPUT
Connection Type | IEC 320-C14 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%)
160-280 VAC (Load at 100%) |
Frequency Range | 40 ~ 70 Hz |
Power Factor | ≥ 0.99 |
OUTPUT
Connection Type |
Standard Model
Long-Run Model
|
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load)
≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port |
BATTERY
Standard Model
Type |
12V / 9Ah |
Numbers | 4 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model
Type |
Depending on the capacity of external batteries |
Number | 6 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input
2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles (IEC C13) 8. Output receptacles (Universal outlet) |


GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 3000 |
Nominal Power (W) | 2700 |
Standard Model
Dimension (mm) |
630 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 29.3 |
Long-run Model
Dimension (mm) |
410 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 14.2 |
INPUT
Connection Type | IEC 320-C20 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC (Load at 50%)
160-280 VAC (Load at 100%) |
Frequency Range | 40 ~ 70 Hz |
Power Factor | ≥ 0.99 |
OUTPUT
Connection Type |
6 x IEC 320-C13 1 x IEC 320-C19 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load)
≤6% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port |
BATTERY
Standard Model
Type |
12V / 9Ah |
Numbers | 6 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Long-run Model
Type |
Depending on the capacity of external batteries |
Number | 6 |
Charging Current (max) | 1A / 2A / 4A / 6A Adjustable |
REAR PANEL
1. AC Input
2. Input circuit breaker 3. USB Communication port 4. RS-232 communication port 5. Intelligent slot 6. External battery connection (Only available for L model) 7. Output receptacles (IEC C13) 8. Output receptacles (Universal outlet) 9. Output receptacle (IEC C19) |


GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 6000 |
Nominal Power (W) | 5400 |
Standard Model
Dimension (mm) |
UPS Unit: 530 x 438 x 88 [2U] (D x W x H) Battery Pack: 668 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | UPS Unit: 15 Battery Pack: 48 |
Long-run Model
Dimension (mm) |
530 x 438 x 88 [2U] (D x W x H) |
Weight (kg) | 15 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240 VAC |
Voltage Range | 110-300 VAC ± 3% at 50% Load
176-300 VAC ± 3% at 100% Load |
Frequency Range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Power Factor | ≥ 0.99 |
OUTPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load)
≤5% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
Standard Model
Type |
12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 9 hours recover to 90% capacity |
Long-run Model
Type |
Depending on the capacity of external batteries |
Number | 16 - 20 pcs (Adjustable) |
Charging Current (max) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
REAR PANEL
|

GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 10000 |
Nominal Power (W) | 9000 |
Standard Model
Dimension (mm) |
UPS Unit: 580 x 438 x 133 [3U] (D x W x H) Battery Pack: 580 x 438 x 133 [3U] (D x W x H) |
Weight (kg) | UPS Unit: 18 Battery Pack: 51 |
Long-run Model
Dimension (mm) |
530 x 438 x 133 [3U] (W x D x H) |
Weight (kg) | 18 |
INPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240 VAC |
Voltage Range | 110-300 VAC ± 3% at 50% Load
176-300 VAC ± 3% at 100% Load |
Frequency Range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Power Factor | ≥ 0.99 |
OUTPUT
Connection Type | Terminal |
Nominal Voltage | 208/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤3% THD (Linear load)
≤5% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
LCD | Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
Standard Model
Type |
12V / 9Ah |
Numbers | 16 |
Typical Recharge Time | 9 hours recover to 90% capacity |
Long-run Model
Type |
Depending on the capacity of external batteries |
Number | 16 - 20 pcs (Adjustable) |
Charging Current (max) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
REAR PANEL
|