Professional II Series (1P/1P)

PRO900-WS/WL SERIES 1-10KVA

True Double-Conversion Online UPS

Mircoprocessor control optimizes reliability

Input power factor correction

Output Power Factor 0.8

Converter mode available

Wide input voltage (110V - 300V)

MODEL

PRO901-WS/WL 1KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 1000
Nominal Power (W) 800
Standard Model

Dimension (mm)

282 x 145 x 220 (D x W x H)
Weight (kg) 9.8
Long-run Model

Dimension (mm)

282 x 145 x 220 (D x W x H)
Weight (kg) 4.1

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Load at 50%)

160-280 VAC (Load at 100%)

Frequency Range 45 ~ 70 Hz
Power Factor >= 0.99

OUTPUT

Connection Type 3 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 2
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 2 or 3
Charging Current (max) 1A / 2A / 4A / 6A Adjustable

REAR PANEL

1. AC Input

2. Input circuit breaker

3. USB Communication port

4. RS-232 communication port

5.  Intelligent slot

6. External battery connection (Only available for L model)

7. Output receptacles

PRO902-WS/WL 2KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 2000
Nominal Power (W) 1600
Standard Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 17
Long-run Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 6.8

INPUT

Connection Type IEC 320-C14
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Load at 50%)

160-280 VAC (Load at 100%)

Frequency Range 45 ~ 70 Hz
Power Factor >= 0.99

OUTPUT

Connection Type 4 x IEC 320-C13
Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 4
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 4 / 6 / 8
Charging Current (max) 1A / 2A / 4A / 6A Adjustable

REAR PANEL

1. AC Input

2. Input circuit breaker

3. USB Communication port

4. RS-232 communication port

5.  Intelligent slot

6. External battery connection (Only available for L model)

7. Output receptacles

PRO903-WS/WL 3KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 3000
Nominal Power (W) 2400
Standard Model

Dimension (mm)

421 x 190 x 318 (D x W x H)
Weight (kg) 27.6
Long-run Model

Dimension (mm)

397 x 145 x 220 (D x W x H)
Weight (kg) 7.4

INPUT

Connection Type IEC 320-C20
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC (Load at 50%)

160-280 VAC (Load at 100%)

Frequency Range 45 ~ 70 Hz
Power Factor >= 0.99

OUTPUT

Connection Type 4 x IEC 320-C13

Terminal

Nominal Voltage 200/208/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 6
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number  6 / 8
Charging Current (max) 1A / 2A / 4A / 6A Adjustable

REAR PANEL

1. AC Input

2. Input circuit breaker

3. USB Communication port

4. RS-232 communication port

5.  Intelligent slot

6. External battery connection (Only available for L model)

7. Output receptacles

8. Output circuit breaker

9. Output terminal

PRO906-WS/WL 6KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 6000
Nominal Power (W) 4800
Standard Model

Dimension (mm)

369 x 190 x 688 (D x W x H)
Weight (kg) 61
Long-run Model

Dimestions (mm)

369 x 190 x 318 (D x W x H)
Weight (kg) 12

INPUT

Connection Type Terminal
Nominal Voltage 208/220/230/240VAC
Voltage Range 110-300 VAC (Load at 50%)

176-300 VAC (Load at 100%)

Frequency Range 46~54 Hz or 56~64 Hz
Power Factor >= 0.99

OUTPUT

Connection Type Terminal
Output Voltage 208/220/230/240VAC
Voltage Regulation  ±1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50Hz or 60Hz +/-0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 16
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 16 ~20 (Adjustable)
Charging Current (max) 1A/2A/4A/6A (Adjustable, 6A is only
available for 16pcs batteries)

REAR PANEL

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slow
  4. USB Communication port
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/output terminal
  9. Maintenance bypass switch (Optional)
PRO910-WS/WL 10KVA

GENERAL

UPS Type Tower
Phase Single phase with ground
Rating (VA) 10000
Nominal Power (W) 8000
Standard Model

Dimension (mm)

442 x 190 x 688 (D x W x H)
Weight (kg) 66
Long-run Model

Dimestions (mm)

442 x 190 x 318 (D x W x H)
Weight (kg) 16

INPUT

Connection Type Terminal
Nominal Voltage 208/220/230/240VAC
Voltage Range 110-300 VAC (Load at 50%)

176-300 VAC (Load at 100%)

Frequency Range 46~54 Hz or 56~64 Hz
Power Factor >= 0.99

OUTPUT

Connection Type Terminal
Output Voltage 208/220/230/240VAC
Voltage Regulation  ±1%
Frequency Range (Synchronized Range)  46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50Hz or 60Hz +/-0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD (Linear load)

≤5% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 16
Typical Recharge Time  9 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Number 16 ~ 20 (Adjustable)
Charging Current (max) 1A/2A/4A/6A (Adjustable, 6A is only
available for 16pcs batteries)

REAR PANEL

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slow
  4. USB Communication port
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/output terminal
  9. Maintenance bypass switch (Optional)

DOWNLOAD

Document Date Version
2015-01-31 1.00
2017-08-07 1.00
2017-08-07 1.00

You may also like…

PRO93100-WS/WL SERIES 10-20KVA

PRO900-VS/VL SERIES 1-3KVA

PRO900-ERS/ERL SERIES 1-10KVA

PRO900-WRS/WRL SERIES 1-10KVA

PRO900-ES/EL SERIES 1-10KVA