Professional II Series (1P/1P) – Rack/Tower - Standard Models - 1KVA to 10KVA
Professional II Series (1P/1P) – Rack/Tower - Standard Models - 1KVA to 10KVA
1000VA
2000VA
3000VA
6000VA
10000VA
At a glance
True double-conversion
Microprocessor control
Input power factor correction
Smart SNMP
Converter mode (optional)


LCD display

Wide input voltage

Zero transfer time

Clean power output

High-precision AVR
Output power factor 0.8
True double conversion online technology


Generator compatible
Works with generator as a power source and converts perfect power to the connected loads.

LCD display
Useful information such as battery health and power conditions are shown at a glance through the LCD display.

Emergency Power Off function
Safety feature that will immediately disconnect the UPS loads from utility power in the event of an emergency to ensure there’s no risk of electrical shock when fire extinguishers or sprinklers are set off inside the room.
(Optional for 1-3kVA, built-in for 6-10kVA)
Explore other UPS series
Prolink offers standalone or modular UPS for every application size in every conceivable context –from a humble server room to the largest data center; low to medium voltage applications; or for various sectors such as factory, transportation, and medical.
Find a suitable UPS for your needs at Prolink.

Capacity
PRO901-WRS 1KVA: 1000VA / 800W
PRO902-WRS 2KVA: 2000VA / 1600W
PRO903-WRS 3KVA: 3000VA / 2400W
PRO906-WRS 6KVA: 6000VA / 4800W
PRO910-WRS 10KVA: 10000VA / 8000W
UPS type
Rack / Tower
Input phase
Single phase with ground
Input nominal voltage
For 1000VA, 2000VA, and 3000VA:
200/208/220/230/240VAC
For 6000VA and 10000VA:
208/220/230/240VAC
Input voltage range
For 1000VA, 2000VA, and 3000VA:
110-300VAC (Based on load at 50%)
160-280VAC (Based on load at 100%)
For 6000VA and 10000VA:
110-300VAC (Based on load at 50%)
176-300VAC (Based on load at 100%)
Input frequency
For 1000VA, 2000VA, and 3000VA:
40 - 70Hz
For 6000VA and 10000VA:
46-54 Hz or 56-64 Hz
Input power factor
≧ 0.99 @ nominal voltage (100% load)
Output voltage regulation
±1%
Output frequency
For 1000VA, 2000VA, and 3000VA:
Synchronized range: 47 - 53Hz or 57 - 63Hz
Battery mode: 50 Hz ± 0.25Hz or 60Hz ± 0.3Hz
For 6000VA and 10000VA:
Synchronized range: 46 - 54Hz or 56 - 64Hz
Battery mode: 50Hz or 60Hz ± 0.1 Hz
Output current crest ratio
3:1
Output harmonic distortion
For 1000VA, 2000VA, and 3000VA:
≦ 3% THD (Linear load)
≦ 6% THD (Non-linear load)
For 6000VA and 10000VA:
≦ 3% THD (Linear load)
≦ 5% THD (Non-linear load)
Battery type and number
1000VA - 12V/9Ah x 2pcs
2000VA - 12V/9Ah x 4pcs
3000VA - 12V/9Ah x 6pcs
6000VA and 10000VA - 12V/9Ah x 16pcs
Battery recharge time
1000VA, 2000VA, and 3000VA:
4 hours to 90% capacity
6000VA and 10000VA:
9 hours to 90% capacity
Charging current
Max 2A
Alarm
Battery mode - Sounding every 4 seconds
Low battery - Sounding every second
Overload - Sounding twice every second
Faulty - Continuously sounding
LCD indicators
Load level, battery level, AC mode, battery mode, bypass mode, and fault indicators
Product
Kindly email support@prolink2u.com for more information.
Product
Kindly email support@prolink2u.com for more information.
Kindly email support@prolink2u.com for more information.
Kindly email support@prolink2u.com for more information.
Quick Compare
PRO901-WRS 1KVA
Professional II Series (1P/1P) – Rack/Tower - Standard Models - 1KVA to 10KVA
1000VA
2000VA
3000VA
6000VA
10000VA
PRO901-WS 1KVA
Professional II Series (1P/1P) - Standard Models - 1KVA to 10KVA
1000VA
2000VA
3000VA
6000VA
10000VA