PRO901-WRS 1KVA

Professional II Series (1P/1P) – Rack/Tower - Standard Models - 1KVA to 10KVA

Professional II Series (1P/1P) – Rack/Tower - Standard Models - 1KVA to 10KVA

Professional II Series (1P/1P) is a single-phase UPS system that uses microprocessor controlled true online double conversion technology to provide protection for critical IT applications.

Kindly email sales@prolink2u.com for purchase or more information. 

1000VA

2000VA

3000VA

6000VA

10000VA

View full details

At a glance

True double-conversion

Microprocessor control

Input power factor correction

Smart SNMP

Converter mode (optional)

LCD display

LCD display

Wide input voltage

Wide input voltage

Zero transfer time

Zero transfer time

Clean power output

Clean power output

High-precision AVR

High-precision AVR

Output power factor 0.8

True double conversion online technology

Generator compatible

Works with generator as a power source and converts perfect power to the connected loads.

LCD display

Useful information such as battery health and power conditions are shown at a glance through the LCD display.

Emergency Power Off function

Safety feature that will immediately disconnect the UPS loads from utility power in the event of an emergency to ensure there’s no risk of electrical shock when fire extinguishers or sprinklers are set off inside the room. 

(Optional for 1-3kVA, built-in for 6-10kVA)

Explore other UPS series

Prolink offers standalone or modular UPS for every application size in every conceivable context –from a humble server room to the largest data center; low to medium voltage applications; or for various sectors such as factory, transportation, and medical.

Find a suitable UPS for your needs at Prolink.

Capacity

PRO901-WRS 1KVA: 1000VA / 800W

PRO902-WRS 2KVA: 2000VA / 1600W

PRO903-WRS 3KVA: 3000VA / 2400W

PRO906-WRS 6KVA: 6000VA / 4800W

PRO910-WRS 10KVA: 10000VA / 8000W

UPS type

Rack / Tower

Input phase

Single phase with ground

Input nominal voltage

For 1000VA, 2000VA, and 3000VA:

200/208/220/230/240VAC

For 6000VA and 10000VA:

208/220/230/240VAC

Input voltage range

For 1000VA, 2000VA, and 3000VA:

110-300VAC (Based on load at 50%)

160-280VAC (Based on load at 100%)

For 6000VA and 10000VA:

110-300VAC (Based on load at 50%)

176-300VAC (Based on load at 100%)

Input frequency

For 1000VA, 2000VA, and 3000VA:

40 - 70Hz

For 6000VA and 10000VA:

46-54 Hz or 56-64 Hz

Input power factor

≧ 0.99 @ nominal voltage (100% load)

Output voltage regulation

±1%

Output frequency

For 1000VA, 2000VA, and 3000VA:

Synchronized range: 47 - 53Hz or 57 - 63Hz

Battery mode: 50 Hz ± 0.25Hz or 60Hz ± 0.3Hz

For 6000VA and 10000VA:

Synchronized range: 46 - 54Hz or 56 - 64Hz

Battery mode: 50Hz or 60Hz ± 0.1 Hz

Output current crest ratio

3:1

Output harmonic distortion

For 1000VA, 2000VA, and 3000VA:

≦ 3% THD (Linear load)

≦ 6% THD (Non-linear load)

For 6000VA and 10000VA:

≦ 3% THD (Linear load)

≦ 5% THD (Non-linear load)

Battery type and number

1000VA - 12V/9Ah x 2pcs

2000VA - 12V/9Ah x 4pcs

3000VA - 12V/9Ah x 6pcs

6000VA and 10000VA - 12V/9Ah x 16pcs

Battery recharge time

1000VA, 2000VA, and 3000VA:

4 hours to 90% capacity

6000VA and 10000VA:

9 hours to 90% capacity

Charging current

Max 2A

Alarm

Battery mode - Sounding every 4 seconds

Low battery - Sounding every second

Overload - Sounding twice every second

Faulty - Continuously sounding

LCD indicators

Load level, battery level, AC mode, battery mode, bypass mode, and fault indicators